12.1-inch Multi-Parameter Patient Monitor - RPM-9000A

12.1-inch Multi-Parameter Patient Monitor, medical monitor, portable patient monitor, ECG monitor - details see: https://www.furniturepopular.com/12-1-inch-multi-parameter-patient-monitor-10018571
Type: Hospital FurnitureGeneral Use: Commercial FurnitureMaterial: MetalMetal Type: Other
Place of Origin: China (Mainland)Brand Name: RisingmedModel Number: RPM-9000A 
12.1-inch Multi-Parameter Patient Monitor
contact supplier for 12.1-inch Multi-Parameter Patient Monitor


  • Standard parameter: ECG, RESP, NIBP, SpO2, TEMP, PR.
  • 12.1" large-screen color TFT display
  • Built-in high-capacity battery, up to 4 hours working time
  • 7-lead ECG waveforms display, big fonts observational interface
  • Reviewable ECG waveforms, Maximum 240 hours reviewing graphic trends
  • Digital SpO2 technique, precise measurement for weak perfusion and finger shaking
  • Arrhythmia and S-T segment analysis and pacemaker detection
  • Protection against interference from defibrillation and electrosurgical Unit
  • Applicable to ICU, CCU, operation, adult, pediatrics and neonatal patient

Standard configuration:

  • ECG, NIBP, SPO2, TEMP, RESP, PULSE, Built-in rechargeable battery

Optional:

  • Thermal printer, Dual TEMP, Single/Dual IBP, EtCO2

Specification:

ECG

Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 15 times/minute to 300 times/minutes
Accuracy: ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Accuracy: Error rate < 20%
Undetected rate < 20%

Analysis function should be started when using the above two kinds of function.

ST section
Scope: ±0.8mV
Precision : < ±0.05mV

SpO2

Detection scope: 0%-100%
Accuracy ±1% 90%-100%
±2% 70%-89%

NIBP

Theory Electric oscillator
Cuff gassing time less than 15 seconds
First-time gassing pressure: dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min(90 min -240min)
Detection scope:
Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure 2.7kPa~31.3kPa (20mmHg~235mmHg)
Detection accuracy
Static pressure: ±3mmHg
Pulse rate: ±2%

Resp

Chest impedance method or concentration of carbon dioxide at end o
f respiration
Scope of chest impedance method 0 time/minute – 100 minutes/minute
Precision of chest impedance method time/minute
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ±1 time/minute

Temp

Single/double path
Type: Vascular/surface temperature
Scope: 20.c~50.c
Accuracy: ±0.2.c

Invasive blood pressure (optional)

Single/double path
Type: direct and continuous detection
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg) 13.33k
Pa(100mmHg) above ±2%
Frequency response:DC-12Hz
Input resistance: not less than 500k
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage: 5V (DC)

Accuracy of sensor: ±2%Isolation voltage: 4 kV

Packaging Detail:carton
Delivery Detail:Within 5 working days after confirming your payment